Abstract
Near surface mounted fiber reinforced polymer reinforcement has become very popular method in strengthening of reinforced concrete structures. The major problem that accompanied the near surface mounted technique is the bond between fiber-reinforced polymers and concrete that corresponds to the stress transfer from concrete into fiber-reinforced polymers. This article presents the test results of pullout tests of near surface mounted glass fiber reinforced polymer bars to investigate the effect of different parameters on the bond performance of this strengthening technique. The test parameters include: adhesive type, groove size, bonded length, environmental condition, and concrete strength. A total of 40 near surface mounted–fiber-reinforced polymer bars, installed in C-shaped concrete blocks, were constructed and tested to failure. Five types of cement and epoxy-based adhesives were used. Two groove sizes and three bonded lengths were also investigated. Normal and high strength concrete were also used. In addition, the effect of two harsh environmental conditions on the performance of the strengthening system was also investigated. The results are presented in terms of pullout loads, free end slip, and mode of failure.
| 1. | Kotynia, R, Filas, L, Lukasiewic, M. Bond aspects of NSM FRP strengthened RC beams. Proceedings of the FRPRCS-9 international conference. 13–15 July 2009. Sydney, Australia. Google Scholar |
| 2. | De Lorenzis, L, Nanni, A. Bond between NSM fiber-reinforced polymer rods and concrete in structural strengthening. ACI Struct J 2002; 99(2): 123–132. Google Scholar |
| 3. | Soliman, SM, El-Salakawy, EF, Benmokrane, B. Flexural behaviour of concrete beams strengthened with near surface mounted FRP bars. Fourth international conference on FRP composites in civil engineering (CICE2008). 22–24 July 2008. Zurich, Switzerland. Google Scholar |
| 4. | De Lorenzis, L, Rizzo, A, La Tegola, A. A modified pull-out test for bond of near-surface mounted FRP rods in concrete. Composites Part B 2002; 33: 589–603. Google Scholar, Crossref |
| 5. | De Lorenzis, L, Teng, JG. Near-surface mounted FRP reinforcement: an emerging technique for strengthening structures. Composites Part B 2007; 38: 119–143. Google Scholar, Crossref |
| 6. | Soliman, S, El-Salakawy, E, Benmokrane, B. Pullout tests of near surface mounted (NSM) CFRP bars. Proceedings of the CSCE 2007 annual general meeting and conference. 6–9 June 2007. Yellowknife, Northwest Territories, Canada. Google Scholar |
| 7. | De Lorenzis, L, Nanni, A. Strengthening of reinforced concrete beams with NSM fiber-reinforced polymer rods. ACI Struct J 2001; 98(1): 60–68. Google Scholar |
| 8. | De Lorenzis L. Strengthening of RC structures with near surface mounted FRP rods. PhD Thesis, Department of Innovation Engineering, University of Lecce, Italy, 2002. Google Scholar |
| 9. | Carolin, A, Taljsten, B. Behaviour of concrete beams strengthened with near-surface mounted reinforcement, NSMR. Proceedings ACIC2002. 15–17 April 2002. Southampton, UK; 177–184. Google Scholar |
| 10. | Yost, JR, Gross, SP, Dinehart, DW. Near surface mounted CFRP reinforcement for the structural retrofit of concrete flexural members. Proceedings ACMBS-IV. 20–23 July 2004. Calgary, Canada. Google Scholar |
| 11. | Hassan, T, Rizkalla, S. Bond mechanism of near-surface-mounted fiber-reinforced polymer bars for flexural strengthening of concrete structures. ACI Struct J 2004; 101(6): 830–839. Google Scholar |
| 12. | Teng, JG, De Lorenzis, L, Wang, B. Debonding failures of RC beams strengthened with near-surface mounted CFRP strips. J Compos Constr ASCE 2006; 10(2): 92–105. Google Scholar, Crossref |
| 13. | Tang, WC, Balendran, RV, Nadeem, A. Flexural strengthening of reinforced lightweight polystyrene aggregate concrete beams with near-surface mounted GFRP bars. Build Environ 2006; 41: 1381–1393. Google Scholar, Crossref |
| 14. | Barros, JAO, Dias, SJE, Lima, JLT. Efficacy of CFRP-based techniques for the flexural and shear strengthening of concrete beams. Cem Concr Compos 2007; 29: 203–217. Google Scholar, Crossref |
| 15. | Choi, HT, West, JS, Soudki, KA. An experimental study on the flexural response of partially bonded FRP strengthened concrete beams. FRPRCS-8. 16–18 July 2007. University of Patras, Patras, Greece. Google Scholar |
| 16. | Kotynia, R. Analysis of the flexural response of NSM FRP-strengthened concrete beams. FRPRCS-8. University of Patras, 16–18 July 2007. Patras, Greece. Google Scholar |
| 17. | Castro, EK, Melo, GS, Nagato, Y. Flexural strengthening of RC “T” beams with near surface mounted (NSM) FRP reinforcements. FRPRCS-8. 16–18 July 2007. University of Patras, Patras, Greece. Google Scholar |
| 18. | Kotynia, R, Filas, L, Lukasiewicz, M. Bond aspects of NSM FRP strengthened RC beams. FRPRCS-9. 13–15 July 2009. Sydney, Australia. Google Scholar |
| 19. | Bolghourjian, N, Soudki, K. Localized NSM GFRP rods for strengthening RC beams. FRPRCS-9. 13–15 July 2009. Sydney, Australia. Google Scholar |
| 20. | Tanarslan, HM. The effects of NSM CFRP reinforcements for improving the shear capacity of RC beams. Constr Build Mater 2011; 25(5): 2663–2673. Google Scholar, Crossref |
| 21. | Bianco, V, Barros, JAO, Monti, G. Three dimensional mechanical model for simulating the NSM FRP strips shear strength contribution to RC beams. Eng Struct 2009; 31(4): 815–826. Google Scholar, Crossref |
| 22. | Rizzo, A, De Lorenzis, L. Behavior and capacity of RC beams strengthened in shear with NSM FRP reinforcement. Constr Build Mater 2009; 23(4): 1555–1567. Google Scholar, Crossref |
| 23. | Oehlers, DJ, Rashid, R, Seracin, R. IC debonding resistance of groups of FRP NSM strips in reinforced concrete beams. Constr Build Mater 2008; 22(7): 1574–1582. Google Scholar, Crossref |
| 24. | Ceroni, F. Experimental performances of RC beams strengthened with FRP materials. Constr Build Mater 2010; 24(9): 1547–1555. Google Scholar, Crossref |
| 25. | Rizzo, A, De Lorenzis, L. Modeling of debonding failure for RC beams strengthened in shear with NSM FRP reinforcement. Composites Part B 2002; 33: 589–603. Google Scholar |
| 26. | Barros, JAO, Dias, SJE. Near surface mounted CFRP laminates for shear strengthening of concrete beams. Cem Concr Compos 2006; 28: 276–292. Google Scholar, Crossref |
| 27. | Nanni, A, Di Ludovico, M, Parretti, R. Shear strengthening of a PC bridge with NSM CFRP rectangular bars. Adv Struct Eng 2004; 7(4): 97–109. Google Scholar, Link |
| 28. | El-Hacha, R, Wagner, M. Shear strengthening of reinforced concrete beams using near-surface mounted CFRP strips. FRPRCS-9. 13–15 July 2009. Sydney, Australia. Google Scholar |
| 29. | Yan, X, Miller, B, Nanni, A, Forde, MC. Characterization of CFRP rods used as near-surface mounted reinforcement. Proceedings of the eighth international structural faults and repair conference. 1999. Engineering Technics Press, CD-ROM version. Edinburgh, Scotland. Google Scholar |
| 30. | Warren GE. Waterfront repair and upgrade. Advanced Technology Demonstration Site No. 3: NAVSTA Bravo 25, Pearl Harbour. Site specific report no. SSR-2567-SHR, 2000. Port Hueneme, CA: FESC. Google Scholar |
| 31. | De Lorenzis, L, Nanni, A. Bond of near-surface mounted FRP rods to concrete. ACI Struct J 2002; 99(2): 123–132. Google Scholar |
| 32. | Bilotta, A, Ceroni, F, Nigro, E. Bond efficiency of EBR and NSM FRP systems for strengthening of concrete members. J Compos Constr ASCE 2011; 15(5): 757–772. Google Scholar, Crossref |
| 33. | Ceroni, F, Pecce, MR, Bilotta, A. Bond behaviour of FRP NSM systems in concrete elements. Composites Part B 2012; 43: 99–109. Google Scholar, Crossref |
| 34. | La Tegola, A, Micelli, F. Environmental effect on RC beams with near surface mounted FRP rods. Sixth international symposium on FRP reinforcement for concrete structures (FRPRCS-6). 8–10 July 2003. Singapore. Google Scholar |
| 35. | Taljsten, B, Carolin, A. CFRP strengthening of concrete beams – testing in sub-zero temperature. Int J Mater Prod Technol 2007; 28(1/2): 29–45. Google Scholar, Crossref |
| 36. | Soliman, S, El-Salakawy, E, Benmokrane, B. Bond performance of near-surface-mounted FRP bars. J Compos Constr 2011; 15(1): 103–111. Google Scholar, Crossref |
| 37. | ACI Committee 440. Guide test methods for fiber reinforced polymer (FRP) for reinforcing or strengthening concrete structures. ACI 440.3R-04, 2004. Farmington Hills, MI, USA: American Concrete Institute. Google Scholar |

